Robin Air 34700 Manual

You have run the machine 10+ hours for vacuum since last oil change. So you have to change vacuum pump oil. For change vacuum pump oil just follow the bellow step: Press main menu then keep pressing up or down arrow key till display show 'CHANGE VACUUM OIL' then press 'YES' key.

Robin Air 34700 Manual

Now vacuum pmp will run for two minute & stop automaticly. When pump stop you just open the oil drain plug & oil fill cap of vacuum pump ( Located oute side of the machine near high & low side hose ) & drain all oil from vacuum pump. After draining used oil,replace oil drain plug & fill new ROBINAIR vacuum pump oil till middel of sight glass.Press 'YES' key & follow on screen messeage. NOTE: Do not over fill the pump & Do not use any COMPRESSOR oil on the vacuum pump! Hope this will help you & if it is please vote for my support.

Answered on Aug 15, 2017. I had a similar problem with a Robinair 17800b. The machine got stuck in Clr or (Clearing) while changing from R-12 to R-134a. If the tank (R-12 or R134a) does not have at least 10 pounds of refrigerant in the tank before you change to another refrigerant, the machine will stay in the clearing process. I called tech support and they walked me through a process that resets the machine. The reset involves entering a code while in r-12 mode, then removing all hoses and switching the switch to R-134a mode and entering another code. The call to the tech line took about 5 mins.

Robinair model 34700

Robinair 34700 Manual Download

The number I called 1-800-822-5561. Answered on Jul 24, 2017. This is a common problem of Robinair 34700Z / 347002K & 347112K series machine. So don't worry just do the following, with POWER SWITCH OFF: - 1# Open front panel cover and verify the ISV tank is not overfilled. If full, carefully remove refrigerant manually from ISV tank by pressing tank valve. 2# verify if there is high pressure in the ISV tank. Purge excess air from the tank manually.

(Open air purge hose from the ISV tank, then carefully press tank valve as needed to blow out excess pressure from the ISV tank) After doing all above stapes and your problem still exist then replace air purge solenoid (Air purge solenoid located near the ISV tank and fixed with automatic air purge device). Hope this will solve your problem, if so please vote for it for farther help! Good luck Answered on Jul 22, 2015.